Excel Sheets

Excel Spreadsheets Engineering

Capacities for Ordinary Bolts to BS449: Part 2

Capacities for Ordinary Bolts The shear strength of a bolt is a measurement of the minimum amount of force needed to break the bolt into two pieces. ...

Crane Girder Design to BS5950-1:2000

Crane girder: The principal horizontal beams of the crane bridge which supports the trolley and is supported by the end trucks. Crane Span: the ...

EXTERNAL WIND PRESSURE (Pe)

EXTERNAL WIND PRESSURE is the physical principle behind the pressure tube (Pitot) or pressure-plate anemometer. ... The wind pressure is also used ...

DYNAMIC WIND PRESSURE (qs)

Dynamic wind load gives rise to vertical motion, creating oscillations in any direction. Like the breaking of an overused violin string, ...

AXIAL COLUMN SHORTENING to EN 1992-1 : 2003

AXIAL COLUMN SHORTENING In tall buildings, columns carry huge loads which effectively compress the column along its axis. This is commonly known as ...

Basement wall design to BS8110:1997, BS8002:1994. BS 8004:1986 etc.

A basement wall is thus one kind of retaining wall. But the term usually refers to a cantilever retaining wall, which is a freestanding structure ...

COLUMN CHART FOR CIRCULAR COLUMNS TO BS 8110:1997

Circular Column: Circular columns are mostly used in piling and elevation of the buildings for aesthetic purposes. In a circular column, more than 4 ...

COLUMN LOAD TAKE DOWN & DESIGN FOR SYMMETRICALLY REINFORCED RECT. COLUMNS BENT ABOUT TWO AXES TO BS 8110:1997

An engineer needs to carry this calculation out for every column and every floor, summing the results at the end to arrive at a cumulative load for ...

FLAT SLAB ANALYSIS & DESIGN to BS 8110:1997

Flat slab is a reinforced concrete slab supported directly by concrete columns without the use of beams. Flat slab is defined as one sided or ...

RIGOROUS RIBBED SLAB DESIGN to BS 8110:1997

Ribbed slabs are slabs cast integrally with a series of closely spaced joists which in turn are supported by a set of beams. The main advantage of ...

RIGOROUS ONE-WAY SOLID RC SLAB DESIGN to BS 8110:1997

The one-way slab is a slab, which is supported by parallel walls or beams, and whose length to breadth ratio is equal to or greater than two and it ...

Spreadsheets for RC Design to BS 8110 and EC2

SPREADSHEETS FOR CONCRETE DESIGN TO BS 8110 and EC2 User Guide to Excel spreadsheet files for contemporary reinforced concrete design to BS 8110: ...

Excel Sheets
Logo
Enable registration in settings - general
Compare items
  • Total (0)
Compare
0